Get a Quote
Home/Solutions/Warehouse & Industry
Solutions 03 · High bay & industrial retrofit

Warehouse & Industrial Lighting

High bay retrofits and new industrial fit-outs supplied as a numbers package: maintained lux on the floor, kWh savings in the tender file, and a delivery plan that keeps operations running while aisles are re-lamped. Choose by zone: UFO rounds for open floor, aisle optics for racking faces, low-temperature ratings for cold rooms, corrosion-coated canopy and flood for yards. The solution fits logistics operators, retrofit contractors and industrial EPCs bidding on payback.

AURELUX warehouse lighting — illustrative photography
Scope of supply

From racking aisles to the yard gate

Industrial scopes are zoned by mounting height, environment and duty cycle — each zone maps to a different product line and control scheme.

AreaRecommended product lineTypical specificationControl & dimming
High-bay racking aislesUFO high bay — industrial seriesAisle optics for vertical illuminance on faces, high-efficacy class, flicker-free driver, IP650-10V / DALI, motion sensor per aisle
Open floor & loading docksLinear high bay, continuous-run tri-proof — industrial seriesWide distribution, IP65, unified mid-bay levelsZone sensors, daylight harvesting at docks
Cold storageLow-temperature rated high bay — industrial seriesDrivers and seals rated for low-temperature duty, IP65Cold-rated motion sensing, switch-derived levels
Production & workshopsTri-proof and linear luminaires — industrial seriesEven functional levels, emergency option for egress routesDALI zoning, emergency test function
Yards & canopyCanopy and flood lines — outdoor & solarIP65/IP66, corrosion-resistant coating, controlled spill lightPhotocell + PIR, curfew profiles via controls

Illustrative prototype specifications — final configuration is confirmed per project. See the data register.

Buying guide

How to choose warehouse lighting

Zone the building first — mounting height and environment pick the product line, the payback model then picks the driver tier.

Specification tierBest forRecommended line
Standard retrofit tier — UFO rounds, motion sensing per aisleOpen floor and standard-height racking aisles in operating warehousesUFO high bay from the industrial series
Aisle & cold-environment tier — aisle optics, low-temperature rated driversNarrow aisles needing vertical illuminance on faces; cold storage and washdown zonesLinear high bay and low-temperature rated high bay from the industrial series
Perimeter tier — corrosion-coated housings, curfew dimming profilesLoading docks, yards and canopy zones exposed to weatherCanopy and flood lines from outdoor & solar, with controls from the smart range

Tier examples follow the scope table above — the final configuration is proven with a pilot aisle before bulk release.

What every solution ships with

Four deliverables, before the first container

Industrial buyers sign off on documents, not brochures. Each solution carries the same four deliverables.

01

Product schedule

Fixture-by-fixture schedule: model, optic, wattage, driver option, mounting and quantity — matched zone by zone to your floor plan.

02

Photometric & Dialux

IES / LDT files plus Dialux layouts at your real rack heights and aisles — maintained lux, uniformity and glare verified before order.

03

Certification mapping

CE for Europe, SASO IECEE + SABER for Saudi, SAA for Australia/NZ — via certified partner factories with certificate numbers and official database checks.

04

Delivery planning

Delivery sequenced with operations: pilot area first, aisles in batches so work never stops the floor, 1-3% spares, consolidated loading.

Industrial strengths

Where this solution earns its keep

Energy-savings calculation for tender files

  • Existing-vs-proposed comparison modeled from your audit inputs
  • Annual kWh and operating cost deltas, ready to paste into bid documents
  • Sensor-based savings scenarios on top of the base retrofit

DLC & North America — quoted case-by-case

  • DLC listings are not our default export line — stated plainly up front
  • Where a tender requires DLC, quoted case-by-case via certified partner factories
  • Qualified-list status verified per product before you commit

Retrofit mapping

  • 1:1 replacement map from your existing fixture schedule and heights
  • Wattage-down conversions that still hold maintained lux
  • Pilot aisle before bulk, so the numbers are proven on your floor
Tender workflows

Numbers that win industrial bids

Warehouse retrofits are approved on payback. We model the existing installation from your inputs — fixture schedule, burning hours, tariff — and return the proposed scheme with annual kWh and cost deltas side by side. The same model drives the Dialux layout, so the lux you promise in the tender is the lux the floor actually gets.

Illustrative project profile — Logistics warehouse retrofit, Jeddah

  • 480 UFO high bays across racking and open floor (illustrative)
  • Pilot aisle verified before bulk release
  • Energy-savings model included in the tender file

Illustrative project profile — replace with verified references.

Compliance snapshot
CEEU · LVD/EMC/RoHS via certified partner factories
UKCAUnited Kingdom
SASO · SABERSaudi Arabia — industrial programs
SAAAustralia / NZ
UL / ETL / DLCNorth America — quoted case-by-case

Certificates are held by certified partner factories, verified per order with certificate number and official database link. Detail in the certification center.

Also on this site
Related product lines

What this solution draws from

Engineering support: for contractors & engineers · custom configuration: OEM / ODM.

Common questions

Industrial sourcing FAQ

Can you produce the energy-savings calculation for our bid?
Yes. From your audit inputs — existing fixture schedule, burning hours, electricity tariff — we return a modeled comparison of annual kWh and operating cost, base retrofit and sensor-enhanced scenarios. The model is illustrative until your metered data confirms it, and we state that in the document.
Can we trial a pilot aisle before committing to bulk?
That is the standard route. Sample quantities (1-5 pcs) ship in 7-14 days courier-tracked; a pilot aisle is sized from your layout and released as a small batch, and bulk production starts only after you confirm the on-floor result.
What MOQ and payment terms apply to industrial projects?
Trial orders from 100-200 pcs, bulk from 500 pcs per item (illustrative — project quantities quoted per schedule). T/T 30% deposit + 70% against B/L copy, L/C at sight available for bulk. Staged delivery is sequenced with your operations calendar.
Further reading

Keep researching

Send the audit. Get the payback model.

Fixture schedule or a site walk video — product schedule, Dialux layout and energy-savings calculation within 24 hours.

Start an inquiry